Zion Tech Group

2 Pcs DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LED Display/5V Micro USB, Smart Home Controller


Price: $8.98
(as of Jan 30,2025 06:05:17 UTC – Details)



Podazz Multi-function Relay Control Module is designed for users with different timing and control needs. It is ideally suited for a wide range of applications from hobby to industrial control.
Specification
Operating Voltage: DC 6V – 30V, supports micro USB 5V power supply.
Operating current: 50mA, quiescent current: 20mA
Operating temperature: -20 to 60
No Maximum Load: Size: 6.4*3.8*1.7 cm

Operation mode:
P1: After the signal is triggered (input voltage), the relay stays on for the OP time and then disconnects. Operation during the OP time is as follows.
1. The retriggered signal is ignored.
2. the retriggered signal is retimed
3. The retriggered signal is reset, the relay contact is broken and the timing is stopped.
4. (Random mode): The relay only performs OP timing once when the power is turned on.

P2: Trigger signal is fed, relay stays open for CL time, then OP time is executed. When the timing is finished, the relay turns off.
1. (Random mode): Trigger signal is fed, the relay stays open for the CL time and then conducts OP time. When the signal is triggered again, the relay stays open for the CL time and then turns on the OP time again.

P3: Trigger signal is fed, the relay conducts OP time, the relay stays disconnected for CL time, then the above action is repeated, and when the signal is triggered again within the timing cycle, the relay contact is disconnected to stop the timing. Loop time (LOP) can be set.
1. No need to trigger the signal when turning on the power, the relay conducts OP time, then the relay stays disconnected CL time, then repeat the above action.

P4: Remaining signal function: Timing reset after signal triggering, relay contact stays on, when there is no signal, the relay closes after timing OP. When the signal is triggered again during the timing period, the timing will be reset.

Timing range: 0.1 sec (min) ~ 999 min (max) continuously adjustable.
How to select timing range:
After setting the parameter value in the mode selection interface, press STOP button briefly to select the timing range.
XXX. Decimal point in single digit, timing range = 1 sec ~ 999 sec.
XX.X Decimal point in 10th digit, timing range = 0.1 sec ~ 99.9 sec.
X.X.X. with all decimal places, range = 1 minute ~ 999 minutes.
For example, if you want to set OP to 3.2 seconds, move the decimal point to the tenth position and the digital tube will display 03.2.

Parameter Description: OP = On Time, CL = Off Time, LOP = Number of Cycles (1 – 999, “—” means infinite)
These parameters are independent of each other, but are shared across all modes of operation. For example, if the OP (on time) is set to 5 seconds in P1.1, and the user needs P1.2 mode, enter P1.2 to set the corresponding parameter, and the OP will also be 5 seconds.
In the main interface (the digital tube displays 000), press the SET button briefly, the OP (CL, LOP) and the corresponding time XXX will be displayed.
If there is only OP (e.g. mode P1.1, P1.2, P1.3) time in the mode, press the SET button briefly to display only OP and the corresponding time.
If there are OP, CL and LOP in the mode (e.g. mode P3.1, P3.2), a short press of the SET button will display OP and the corresponding time, CL and the corresponding time, LOP and the corresponding time.

After setting the operation mode, press the SET button on the main interface to easily view and change the parameters.

How to Set Parameters
1. First, determine the operating mode of the relay. 2.
2. After determining the operating mode of the relay, in the main interface (when the module is powered up, it will flash the current operating mode – default is P1 mode, then enter the main interface)
Long press the SET button for 2 seconds and then release it to enter the mode selection interface, select and set the mode (P1 ~ P-4) by short press the UP and DOWN buttons.
3. Select the desired setting mode (e.g. P3-1) and press the SET button briefly to set the parameters. At this time, the parameter you set will blink (OP – ON time, CL – OFF time, LOP – number of cycles). You can adjust the parameters by pressing the UP and DOWN buttons. Long press (fast increase or decrease) and short press (increase or decrease by 1 unit) are supported. After the parameter setting is completed, short press “STOP” button to select the unit point position and choose the timing range (corresponding to the time 0.1 seconds ~ 999 minutes). Short press “SET” (set) key to set the next parameter of the current mode, the progress is as described above.
4. After selecting the mode parameter, press and hold the “SET” button for 2 seconds and release. The current setting mode will blink and return to the main interface, parameter setting is complete. Very simple!

Main interface:
Off” state displays “000” without decimal point; “On” state displays clear decimal point.
Mode selection interface:
Long press “SET” key to set parameters, long press “SET” key to return to the main interface. Very simple!
Relay Enable Mode:
ON: Relay is allowed to conduct during OP time (on time).
OFF: The relay is forbidden to conduct and is always off.
Short press the “STOP” button on the main interface to switch between “ON” and “OFF”. It will blink and return to the main interface at this time. (This function is an emergency stop function, which can turn on or off the relay with one button)

Sleep Mode:
C-P Sleep mode: When the relay is not used for 5 minutes, the digital tube will automatically turn off the display and the program will continue to work.
O-d Normal Mode: The digital tube display is always on. Press and hold the “STOP” button for 2 seconds and release it to toggle between C-P and O-d states. It will blink and return to the main interface.
After power failure, the sleep mode will automatically switch to normal mode.

Package Includes:
2 x DC 6-30V Timer Relay Module with LED display, paper manual not included)

Caution:
Before using, please check whether the relay enable mode is set to “ON” to ensure the full function of the relay. On the main interface, short press the “STOP” button to toggle between “ON” and “OFF”.
If the timing relay board is not energized, or if the timing relay board is energized but the loads in the circuit do not trigger the start, try applying more power than expected. This is especially true when used with trigger signals and loads on the wiring diagram that share a common power source, as they require additional power to start.
Press and hold the “DOWN” key to toggle between F1 and F2 modes. f1 is the default mode: relay operates in forward direction and f2 is the opposite mode: relay operates in reverse direction. Some batches do not include this feature as F2 mode is rarely used.
Package Dimensions ‏ : ‎ 3.66 x 3.58 x 1.65 inches; 2.4 ounces
Item model number ‏ : ‎ DC 6-30V
Date First Available ‏ : ‎ June 28, 2024
Manufacturer ‏ : ‎ Podazz
ASIN ‏ : ‎ B0D89Y7KHZ
Country of Origin ‏ : ‎ China

Multi-functional Timing Relay: Programmable delay mode control relay timing, widely used in smart home, industrial control, automatic irrigation, indoor ventilation, protection equipment and so on.
Operating voltage: DC 6V – 30V, supports micro USB 5V power supply. High Level Trigger: 3V – 24V, NO (Normally Open) Maximum Load < AC 250V/10A, < DC 30V/10A, Timing Range 0.1 sec ~ 999 min (Continuously Adjustable).
Hibernation Mode: If there is no operation for 5 minutes, the digital tube of the relay board will turn off automatically. Press any button to wake it up.
Parameter description: OP (on time) / CL (off time) / LOP (loop time) can be set individually, the parameters are independent of each other. All parameters are permanently stored once set. Functions and parameters can be viewed or changed later.
Reverse Protection: Built-in diode to provide accidental polarity reversal protection for the circuit.


Introducing the 2 Pcs DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LED Display/5V Micro USB – the ultimate smart home controller for all your timing needs!

This programmable timer relay module is designed to make your life easier by allowing you to set specific on/off times for your devices. With a wide voltage range of 6-30V, this module is versatile and can be used with a variety of electronic devices.

The LED display makes it easy to program and monitor the timing settings, while the 5V Micro USB port allows for convenient power input. Whether you’re looking to automate your lighting, irrigation system, or any other electrical appliance, this timer relay module is the perfect solution.

Say goodbye to manual timers and hello to the convenience of a programmable cycle timer. Upgrade your home automation system with the 2 Pcs DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer today!