Zion Tech Group

Tag: 126S

  • Smart Air Quality Meter Indoor 11-in-1 Air Monitor PM1.0 PM2.5 PM10 Dust TVOC VOC Detector HCHO Tester with Data Record for Home Office (126S)

    Smart Air Quality Meter Indoor 11-in-1 Air Monitor PM1.0 PM2.5 PM10 Dust TVOC VOC Detector HCHO Tester with Data Record for Home Office (126S)


    Price: $179.99
    (as of Dec 20,2024 19:51:23 UTC – Details)


    Product Description

    BLATN Air quality monitor 126s

    BLATN Air quality monitor 126s

    BLATN air quality monitor indoor

    BLATN air quality monitor indoor

    BLATN 126s smart air quality monitor

    PM and particle number

    1. PM1.0, PM2.5, PM10

    Unit: μg/m3 (Micrograms per cubic meter)

    Refers to the concentration of particulate matter in the environment, a unit of mass

    PM2.5: is the total mass of all particles with a diameter of less than Or equal to 2.5 microns in the ambient air per cubic meter

    PM10: is the total mass of all particles with a diameter of less than Or equal to 10 microns in the ambient air per cubic meter

    2. 6-channel particle number: >0.3 >0.5 >1.0 >2.5 >5.0 >10

    Unit: Num/L (number/liter, Number per liter of air)

    It is a unit of quantity

    >5.0 : The number of particles greater than 5.0 refers to the total number of particles greater than 5 microns in diameter per liter of air

    >10: The number of particles greater than 10 refers to the total number of particles greater than 10 microns in diameter per liter of air

    Product highlights

    6-channel particle counter

    6-channel particle counter

    6-channel Particle Meter

    Air particle detector-High precision laser particle sensor

    User can view 6-channel particle counter 0.3 0.5 1.0 2.5 5.0 10 and PM1.0 reading by switching the Curve Button (mode switch button)

    PM0.3
    PM0.5
    PM1.0
    PM2.5
    PM5.0
    PM10

    Data logging function

    Data logging function

    Data logging & Data Export

    TF memory card can storage 100K+ data records

    Data recording frequency: once a minute
    Connect the computer via Card Reader
    Data records can be exported in TXT file
    You can use Excle to open TXT files to analyze data trends

    Data curve function

    Data curve function

    Quality design

    2.4-inch TFT liquid crystal display
    Energy absorption seismic design
    Data curve trend

    Product function

    aqi meter AQI Alarm

    aqi meter AQI Alarm

    Air Quality Monitor Alarm

    Air quality alarm threshold base on US standard:

    PM2.5: 0-12μg/m³ Good
    PM10: 0-54μg/m³ Good
    CO2: 400-700ppm Good
    TVOC: 0-5.0mg/m³ Good
    HCHO: 0-0.1mg/m³ Good

    3-way circular air convection

    3-way circular air convection

    3-way Circular Air Convection

    Active air interaction system
    increases contact area with the sensor
    mute fan with low noise

    Rechargeable lithium battery

    Rechargeable lithium battery

    Rechargeable Lithium Battery

    rechargeable lithium battery
    Mini USB charging port

    Add to Cart

    Add to Cart

    Customer Reviews

    4.0 out of 5 stars

    2

    4.5 out of 5 stars

    2

    Price
    $179.99$179.99
    $209.99$209.99

    PM1.0

    PM2.5

    PM10

    TVOC

    Formaldehyde

    CO2

    Particle meter 0.3 0.5 1.0 2.5 5.0 10

    Data record & Data Export

    Fault description:

    The machine suddenly shut down by itself, rebooting only lasts a second or two, or it can not turn on.
    The machine cannot be turned on after charging, black screen

    Solution: If the TF memory card is full, please replace it with a new card in time. Otherwise, there may be a sudden automatic shutdown of the machine, and can not open the machine.

    If the above problems occur, try the following steps to rectify the fault:

    1. Take out the TF memory card on the bottom of the machine 2. After power off, connect the charger to charge for more than 6 hours and then turn it on without the TF memory card to see if it can work.

    Regarding machine reading is high on first use Solution: After receiving the machine, put it in an outdoor clean and ventilated environment for about 8 hours, so that the charge can be released. (Charger can be connected to ensure the power supply)

    Regarding the high TVOC level

    Please check your measuring point if there are some human activities such as cooking, smoking, drinking or some chemical gases such as perfume, air freshener, detergent, etc.

    Then try to put the machine in an outdoor clean and ventilated environment for more than 3 hours to see if the machine value will drop ( formaldehyde is about 0.02. TVOC and particulate matter are based on your local environment, but TVOC is usually lower outdoors than indoors, unless there are a lot of car exhaust, bakery and factory emissions around you).

    If the TVOC reading of the machine is high when it is placed indoors, but TVOC reading drops when it is placed outdoors in a well-ventilated place, it proves that there is no problem with our sensor, which is completely logical. Place to outdoor the reading drop but place to indoor reading rise proves that there must be air in the room that affects the sensor reading.

    About TVOC and HCHO calibration:

    We should calibrate the equipment in fresh outdoor air, because particulate pollution and chemical pollution are two different types of pollution. Very low particulate matter does not mean that chemical pollution and interfering gases do not exist.

    Our sensor calibration function is for formaldehyde and TVOC. You can put the machine in an outdoor well-ventilated place for 2hours to see if the readings of formaldehyde and TVOC exceed the standard. If all the readings of formaldehyde and TVOC are very low, you can calibrate it.

    Our machine calibration: 1. The machine leaves the factory with our calibrated formaldehyde zero point as the zero point, and restoring the factory settings will also restore to our factory calibrated zero point. 2. If you calibrate the device on site, the device will use the current calibration environment as the zero point. 3. After you finish the calibration, if the current calibration environment formaldehyde value is higher than the factory calibration zero point, it will be displayed as a positive number in the calibration setting interface of the machine.

    If the current calibration environment formaldehyde value is lower than the factory calibration zero point, it will display Is negative.

    4. Under normal use, frequent calibration is not required.

    How to open TXT data record file with excle 1. Create a new excel document 2. Click on the file to open a new document, select all files, and open the data storage file Save.txt 3. Select Fixed width-add space to align each paragraph of characters, click Next, column data format, select Normal, and then click Finish

    【Laser Particle Sensor】BLATN air quality detector adopts a high-precision laser fine dust sensor, which can detect air particles 0.3; 0.5; 1.0; 2.5; 5.0; 10 microns. It can real-time monitor the concentration of particulate matter PM1.0 PM2.5 PM10 in the air
    【Real-time monitoring of indoor air quality】Indoor air quality meter can continuously monitor the air quality in your home, office, or other indoor outdoor environments, can display the real-time data of PM2.5, PM1.0, PM10, TVOC, VOC, HCHO formaldehyde and 6-channel tiny particle number in the air
    【Portable and Easy to Use】Home air quality testing kit has a small size and lightweight design, which is convenient to carry and use. It can be placed on a desk or carried in your pocket, making it suitable for home, office, and travel use
    【Data logger】Indoor air quality sensor has a built-in TF memory card which can store up to 10W+ pcs of data records. You can download the data to your computer through the card reader in TXT file and analyze it
    【Multiple applications】Indoor air quality analyzer is suitable for check the air pollution in your home and testing the chemical gas. It can be used to monitor air quality for allergies, asthma, and more. HAP hazardous airborn pollutant Standards Index indicate


    Introducing the Smart Air Quality Meter Indoor 11-in-1 Air Monitor PM1.0 PM2.5 PM10 Dust TVOC VOC Detector HCHO Tester with Data Record for Home Office (126S)!

    Are you concerned about the air quality in your home or office? Look no further than this advanced air monitor that can detect PM1.0, PM2.5, PM10, dust, TVOC, VOC, and formaldehyde levels. With its 11-in-1 design, this device provides comprehensive monitoring to ensure you and your loved ones are breathing clean and healthy air.

    The Smart Air Quality Meter also comes equipped with a data recording feature, allowing you to track changes in air quality over time and make informed decisions to improve the environment in your living or working space. With its sleek and compact design, this monitor is perfect for any room and can be easily integrated into your existing setup.

    Don’t compromise on the air you breathe – invest in the Smart Air Quality Meter Indoor 11-in-1 Air Monitor for a healthier and happier home or office environment.
    #Smart #Air #Quality #Meter #Indoor #11in1 #Air #Monitor #PM1.0 #PM2.5 #PM10 #Dust #TVOC #VOC #Detector #HCHO #Tester #Data #Record #Home #Office #126S

Chat Icon